POCT Immunofluorescence Quantitative Analyzer, IFA-S1000
POCT Immunofluorescence Quantitative Analyzer IFA-S1000 memiliki kecepatan uji 240 kali/jam, rentang panjang gelombang 740nm, dan sumber cahaya eksitasi LED.
Yang akan anda dapatkan jika membeli POCT Immunofluorescence Quantitative Analyzer, IFA-S1000 dari kami
- ✓
Garansi Resmi Prinsipal
Unit didistribusikan resmi dengan garansi prinsipal sesuai ketentuan pabrikan.
- ✓
Instalasi & Training
Teknisi kami membantu instalasi dan pelatihan penggunaan alat di lokasi Anda.
- ✓
Dukungan Teknis & Sparepart
Layanan purna jual, konsultasi teknis, dan ketersediaan suku cadang.
- ✓
Opsi Kalibrasi
Tersedia layanan kalibrasi tertelusur untuk menjaga akurasi instrumen.
Spesifikasi Teknis
| Parameter | IFA-S1000 |
|---|---|
| Test Item | The product is used cooperatively with immunofluorescence assay kit produced by our company. |
| Excitation Light Source | LED |
| Wavelength Range | 740nm |
| Test Item Parameter | The user can read configuration parameters of the instrument from information card. |
| Sample Type | Whole blood, serum, plasma, urine and faeces (subject to specification of immunofluorescence assay kit) |
| Delay Test | Delay test time can be set. Place test card in the instrument and test at fixed time after completion of reaction |
| Test Speed | 240 times/hour |
| Background Number | Fluorescence value should be ≤5 |
| Repeatability | The variable coefficient of fluorescence value of fluorescence test cards of different intensities repeatedly measured by the instrument CV≤2.0% |
| Stability | The relative deviation between the test result at 4th hour and the 8th hour after the instrument is working stably and the test result when the instrument just works stably is limited to ±3.0%. |
| Accuracy | When the instrument tests the calibrated fluorescence test card, the deviation between the measured fluorescence value and the calibration value of the fluorescence test card is ±3.0%. |
| Measuring Time | The time from inserting the fluorescence test card to displaying the test result should not exceed 15s. |
| Linearity Range | Within the concentration range of standards no less than two orders of magnitudes, the linearly dependent coefficient of the fluorescence value and concentration read by the instrument r≥0.990 |
| Electricity | AC 100V-240V 50Hz/60Hz; Host: DC12V 5A |
| Input Power | 60 VA |
| Dimension | 200*300*140mm |
| Net Weight | 2.0kg |
Menu of assays
Geser tabel ke samping untuk melihat seluruh 6 varian model.
| Parameter | Product Item | Specimen | Reaction Time | Measuring Range | Clinical Range | Intended Use |
|---|---|---|---|---|---|---|
| Cardiac | cTnl | WB/Serum/Plasma | 12min. | 0.1-40ng/mL | <0.3ng/mL | Several heart diseases including myocardial infarction and heart failure.; Myo WB/Serum/Plasma 12min. 5-400ng/mL <58ng/mL Acute myocardial infarction (AMI) in early stage.; CK-MB WB/Serum/Plasma 12min. 1-200ng/mL <5ng/mL Acute myocardial infarction (AMI) in early stage.; NT-proBNP WB/Serum/Plasma 10min. 20-35000pg/mL Under75:0~347pg/mL Over75:0~449pg/mL Heart failure.; D-Dimer WB/Plasma 10min. 40-10000ng/mL <500ng/mL Disseminated intravascular coagulation (DIC),deep vein thrombosis (DVT),pulmonary embolism (PE), myocardial infarction, cerebral infarction,etc.; cTnl+Myo+ CKMB WB/Serum/Plasma 12min. Same with single item Same with single item Triple marker of myocardial infarction.; ST2 WB/Serum/Plasma 10min. 10-400ng/mL <35ng/mL Heart failure.; Lp-PLA2 WB/Serum/Plasma 10min. 10-900ng/mL <175ng/mL Risk evaluation of ACS and atherosclerotic ischemic stroke patients.; H-FABP WB/Serum/Plasma 10min. 2.5-160ng/mL <5ng/mL Acute myocardial infarction (AMl) in early stage.; HCY WB/Serum/Plasma 15min. 1-50μmol/L 5-15μmol/L Atherosclerosis, venous embolism, coronary heart disease. |
| Inflammation | CRP/hs-CRP | WB/Serum/Plasma | 3min. | 0.5-200mg/L | CRP<10mg/L hs-CRP<1mg/L | Nonspecficity inflammatory marker.; SAA WB/Serum 5min. 1-200mg/L <10mg/L Inflammation &infection.; PCT WB/Serum/Plasma 10min. 0.2-100ng/mL <0.5ng/mL Sepsis.; CRP+SAA WB/Serum/Plasma 5min. Same with single item Same with single item Inflammation &infection.; IL-6 WB/Serum/Plasma 10min. 5-4000pg/mL 10pg/mL Diabetes, rheumatoid arthritis,etc.; Calprotectin Fecal specimens 10min. 5-1000mg/g <50mg/g Enteritis. |
| Thyroid Hormone | TSH | WB/Serum/Plasma | 15min. | 0.3-100mU/L | 0.3-4.2mU/L | Hyperthyroidism and hypothyroidism.; T3 WB/Serum/Plasma 15min. 0.5-10nmol/L 1.23-3.07nmol/L Thyroid dysfunction.; Tπ4 WB/Serum/Plasma 15min. 5-300nmol/L 66-181nmol/L Thyroid dysfunction.; FT3 WB/Serum/Plasma 15min. 1-50pmol/L 3.1-6.8pmol/L Thyroid dysfunction.; FT4 WB/Serum/Plasma 15min. 5-100pmol/L 12-22pmol/L Thyroid dysfunction. |
| Tumor Maker | AFP | WB/Serum/Plasma | 10min. | 2.5-200ng/mL | <20ng/mL | Pregnancy cancer.; CEA WB/Serum/Plasma 10min. 1-200ng/mL <5ng/mL Colon cancer, colorectal cancer,etc.; NSE WB/Serum/Plasma 10min. 1-400ng/mL <16ng/mL Non-small cell lung cancer.; FOB Fecal specimens 10min. 50-1000ng/mL <100ng/mL Abnormal recessive gastrointestinal bleeding.; PGIⅡI WB/Serum/Plasma 10min. 1-100ug/L PGI/PGII>3.0 Gastric abnormalities.; PGI WB/Serum/Plasma 10min. 2.5-200ug/L >70ng/mL Gastric abnormalities.; TPSA WB/Serum/Plasma 10min. 0.5-40ng/mL <4ng/mL Prostate cancer.; FPSA WB/Serum/Plasma 10min. 0.1-10ng/mL <1ng/mL Prostate cancer.; CA12-5 WB/Serum/Plasma 10min. 20-500U/mL <35U/mL Ovarian cancer.; CA15-3 WB/Serum/Plasma 10min. 10-400U/mL <25U/mL Breast cancer.; HE4 WB/Serum/Plasma 10min. 50-2000pmol/L <140pmol/L Ovarian cancer.; CA19-9 WB/Serum/Plasma 10min. 10-400U/mL <27U/mL Pancreatic cancer.; HCG WB/Serum/Plasma 10min. 5-400mIU/mL <10mIU/mL Early pregnancy, ectopic HCG cancer, incomplete abortion.; CK19 (Cyfra21-1) WB/Serum/Plasma 10min. 1-100ng/mL <3.3ng/mL Non-small cell lung cancer. |
Fitur Utama
- Sensitivitas ultra-tinggi dan presisi yang sangat baik.
- Cepat dan fleksibel, hasil dalam waktu singkat.
- Manajemen kode QR cerdas.
- Transmisi data real-time, kompatibel dengan LIS/HIS.
- Menyimpan 10.000 hasil.
- Layar LCD sentuh besar.
Aplikasi
POCT Immunofluorescence Quantitative Analyzer digunakan bersama strip reagen fluoroimmunoassay khusus dan cocok untuk fluoroimmunoassay sampel tubuh manusia. Produk ini dapat digunakan untuk immunoassay semikuantitatif dan kuantitatif pada institusi medis, antiepidemi, dan penelitian ilmiah.