| — | GC-906 |
|---|
| Host | Host / Pressure/Flow Control / Supports up to 18 channels of electronic pressure/flow control (EPC) |
|---|
| Host | Host / Pressure Control Accuracy / 0.001psi |
|---|
| Host | Host / Number of sample ports supported / 3 |
|---|
| Host | Host / Maximum number of detectors supported / 4 |
|---|
| Host | Host / Temperature Control System / 8-channel independent temperature control system |
|---|
| Host | Host / Smart Maintenance Tracking and Reminders / yes |
|---|
| Column oven | Column oven / Control temperature / Room temperature+2℃ ~ 450℃ |
|---|
| Column oven | Column oven / Minimum step value / 0.01℃ |
|---|
| Column oven | Column oven / Maximum heating rate / ≥250ºC/min |
|---|
| Column oven | Column oven / Cooling time / From 450°C to 50°C in <3.2 minutes |
|---|
| Column oven | Column oven / Programmed Temperature Ramp / ≥99 steps 100 Platform |
|---|
| Column oven | Column oven / Temperature Stability / Ambient temperature ±1°C, column oven temperature variation <0.01°C |
|---|
| Column oven | Column oven / Others / 1. Automatic furnace chamber temperature protection function 2. Dual column box independent temperature control |
|---|
| Injection System | Injection System / Injection type / Compatible with split/splitless capillary injectors, septum purging packed column injectors, cold column head injectors, programmable temperature vaporization injection ports, valve injection systems, headspace injection systems, thermal desorption injection systems, etc. |
|---|
| Injection System | Injection System / Maximum operating temperature / 450℃ |
|---|
| Injection System | Injection System / Programmatic current increase / ≥ 10 steps |
|---|
| Injection System | Injection System / Stem pressure / 0~50psi、0-200psi |
|---|
| Injection System | Injection System / Pressure Control Accuracy / 0.001Psi |
|---|
| Injection System | Injection System / Maximum bypass ratio / 1: 10000 |
|---|
| Injection System | Injection System / Flow Setting Range / 0~500ml/min 0~1250ml/min |
|---|
| Injection System | Injection System / Flow Setting Accuracy / 0.01ml/min |
|---|
| Injection System | Injection System / Carrier Gas Control Mode / Constant pressure, constant flow rate, constant linear velocity, programmed pressure, programmed flow rate, programmed linear velocity, pulse injection |
|---|
| Injection System | Injection System / Others / Features an independent split cold trap and a septum purge trap |
|---|
| Detector | Hydrogen Flame Ionization Detector (FID) / Maximum operating temperature / 450℃ |
|---|
| Detector | Hydrogen Flame Ionization Detector (FID) / Detection limit / ≤1.1pg C/s (n-hexadecane) |
|---|
| Detector | Hydrogen Flame Ionization Detector (FID) / Baseline drift (30 min) / ≤2×10⁻¹³A |
|---|
| Detector | Hydrogen Flame Ionization Detector (FID) / Baseline noise / ≤2×10^⁻¹⁴A |
|---|
| Detector | Hydrogen Flame Ionization Detector (FID) / Dynamic Linear Range / ≥10⁷ |
|---|
| Detector | Hydrogen Flame Ionization Detector (FID) / Function / Auto-ignition function |
|---|
| Detector | Thermal Conductivity Detector (TCD) / Sensitivity / ≥12000mV.mL/mg |
|---|
| Detector | Thermal Conductivity Detector (TCD) / Baseline drift (30 min) / ≤0.2mV |
|---|
| Detector | Thermal Conductivity Detector (TCD) / Baseline noise / ≤0.05mV |
|---|
| Detector | Thermal Conductivity Detector (TCD) / Dynamic Linear Range / ≥10⁵ |
|---|
| Detector | Thermal Conductivity Detector (TCD) / Function / Air Gap Flow Protection Function |
|---|
| Detector | Flame Photometric Detector(FPD) / Maximum operating temperature / 450℃ |
|---|
| Detector | Flame Photometric Detector(FPD) / Detection limit / P≤80fg/s (Methyl parathion) 、S≤8pg/s (Methyl parathion) |
|---|
| Detector | Flame Photometric Detector(FPD) / Dynamic Linear Range / P≥10³;S≥10² |
|---|
| Detector | Flame Photometric Detector(FPD) / Function / Auto-ignition function |
|---|
| Detector | Electron Capture Detector (ECD) / radioactive source / 63Ni |
|---|
| Detector | Electron Capture Detector (ECD) / Maximum operating temperature / 400℃ |
|---|
| Detector | Electron Capture Detector (ECD) / Detection limit / ≤1.0×10⁻¹⁴ g/mL (γ-666) |
|---|
| Detector | Electron Capture Detector (ECD) / Dynamic Linear Range / ≥10⁴ |
|---|
| Detector | Nitrogen-Phosphorus Detector (NPD) / Maximum operating temperature / 400℃ |
|---|
| Detector | Nitrogen-Phosphorus Detector (NPD) / Detection limit / N: ≤1×10⁻¹²g(N)/s(Azonaphthalene) P: ≤5×10⁻¹³g(P)/s(Malathion) |
|---|
| Detector | Nitrogen-Phosphorus Detector (NPD) / Dynamic Linear Range / N≥10³、P≥10³ |
|---|