Kembali ke katalog
Grating Portable Spectrophotometer, SP-CLR606 — Spektrofotometer & Colorimeter

Foto produk resmi · 1 tampilan

General Lab

Grating Portable Spectrophotometer, SP-CLR606

SP-CLR606

Grating Portable Spectrophotometer SP-CLR606 bekerja pada rentang panjang gelombang 360-780nm dengan pitch 10nm, konfigurasi hardware tinggi, dan sensor CMOS double array 256 elemen.

Yang akan anda dapatkan jika membeli Grating Portable Spectrophotometer, SP-CLR606 dari kami

  • Garansi Resmi Prinsipal

    Unit didistribusikan resmi dengan garansi prinsipal sesuai ketentuan pabrikan.

  • Instalasi & Training

    Teknisi kami membantu instalasi dan pelatihan penggunaan alat di lokasi Anda.

  • Dukungan Teknis & Sparepart

    Layanan purna jual, konsultasi teknis, dan ketersediaan suku cadang.

  • Opsi Kalibrasi

    Tersedia layanan kalibrasi tertelusur untuk menjaga akurasi instrumen.

Spesifikasi Teknis

ParameterSP-CLR606
Optical GeometryReflect: di:8°, de:8°(diffused illumination, 8-degree viewing angle) ; SCI (specular component included)/SCE (specular component excluded) ; Include UV / excluded UV light source Transmittance: di:0°, de:0° (diffuse illumination: 0° viewing) ; SCI (specular component included)/SCE (specular component excluded) ; Include UV / excluded UV light source; Haze(ASTM D1003), Conforms to CIE No.15,GB/T 3978,GB 2893,GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7
ApplicationIt is used for accurate analysis and transmission of laboratory color.It can be applied in paints, inks, textiles, garments, printing and dyeing, printing and other industries for color transfer and quality control.
Integrating Sphere SizeΦ154mm
Light Source360 nm to 780 nm, Combined LED Light, 400nm cut-off light source,420nmCut-off light source
Spectrophotometric ModeConcave Grating
Sensor256 Image Element Double Array CMOS Image Sensor
Wavelength Range360-780nm
Wavelength Interval10nm
Semiband Width5nm
Measured Reflectance Range0-200%
Measured ApertureReflective : Φ30mm/Φ25.4mm, Φ18mm/Φ15mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm; Transmissive : Φ25.4mm; Remark: 1. Automatic identification of switch caliber 2. Customized Configuration caliber and lens position
Specular ComponentReflectance: SCI&SCE / Transmittance: SCI&SCE
Color SpaceCIE LAB,XYZ,Yxy,LCh,CIE LUV,Musell,s-RGB,HunterLab,βxy,DIN Lab99
Color Difference FormulaΔE * ab ,ΔE * uv ,ΔE * 94 ,ΔE * cmc(2:1) ,ΔE * cmc(1:1) ,ΔE * 00 , DINΔE 99 ,ΔE (Hunter),
Other Colorimetric IndexWI (ASTM E313, CIE/ISO, AATCC, Hunter), YI (ASTM D1925, ASTM 313), TI (ASTM E313, CIE/ISO), MI (Metamerism Index), Staining Fastness, Color Fastness, Color Strength, Opacity, 8° Glossiness,Gardner Index, Pt-Co Index, 555 Index, Haze(ASTM D1003)Saybolt, Color Code (ASTM D1500)
Observer Angle2°/10°
IlluminantD65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,DLF,TL83,TL84,TPL5,U30
Displayed DataSpectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset
Measurement TimeAbout 2.4s (Measure SCI & SCE about 5s)
RepeatabilitySpectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.04% (400 nm to 700 nm: within 0.04%) Chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.01 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration) Spectral Transmittance: Φ25.4mm/SCI, Standard deviation within 0.05% (400 nm to 700 nm: within 0.04%) Chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.02 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration)
Inter-instrument ErrorΦ25.4mm/SCI, Within ΔE*ab 0.12; (Average for 12 BCRA Series II color tiles)
DimensionL*W*H=370x300x200mm
WeightApprox. 9.6kg
PowerAC 24V, 3A Power adapter power supply
Illuminant Life Span5 years, more than 3 million times measurements
Display7-inch TFT color LCD, Capacitive Touch Screen
Data PortUSB & Bluetooth & Print serial port
Data StorageStandard 5000 Pcs, Sample 40000 Pcs
LanguageSimplified Chinese, Traditional Chinese, English, (Optional Customized German, French and Spanish)
Operating Environment0~40℃, 0~85%RH (no condensing), Altitude < 2000m
Storage Environment-20~50℃, 0~85%RH (no condensing)
Standard AccessoryPower Adapter, User Guide, CD Disk(PC Software), USB cable, Standard Calibration Board, Black Calibration Cavity, Transmission black baffle, Sample holder, 25.4 caliber, 15 caliber, 8 caliber, 4 caliber,Transmissive Test Component, Micro Aperture(4mm) transmission test clamp component
Optional AccessoryMicro Aperture(4mm) transmission test clamp component
Notes:The specifications are subject to change without notice.

Butuh penawaran resmi untuk produk ini?

Tim sales kami akan mengirimkan quotation lengkap (harga, lead time, biaya instalasi) dalam 1×24 jam kerja.